| CHAPTER 13 | 
| AVIATION GASOLINE AND LUBRICATION BILL | 
	- General
		
			- The Air Officer is charged with the operation and maintenance of the gasoline and
			aviation lubricating oil systems. The Machinist of the Air Department shall act as the
			fueling officer, and will have direct charge of the gasoline and lubricating oil systems.
			The personnel of the gasoline and oil details, and no others, shall operate the systems.
- Every officer and man is especially enjoined to exercise the utmost care and continual
			vigilance to prevent the explosions and fires which may attend the handling and use of
			such large quantities of gasoline as are required in the operation of the systems.
- Personnel assigned to the gasoline and oil details shall be required to pass a
			satisfactory examination before being detailed to this duty, such examination to be given
			by the Air Officer, or his assistant.
 
- Description of The Systems
		
			- Gasoline System
				
					- There are ten gasoline storage tanks. These tanks are divided into two groups,
					the forward group consisting of four tanks in the two forward compartments, and the
					after group consisting of six tanks in the two after compartments. The system operates
					on a combined hydraulic gravity and pressure system, with salt water gravity tanks
					supplying sufficient head to permit suction by the motor and water turbine driven
					gasoline pumps which supply gasoline to the outlets under pressure. The salt water
					overflow is used when filling and securing the system. The tanks are of galvanized
					mild steel and are separated from the ship's structure by a void of sufficient size
					to allow inspection of the exterior of each tank. The void is under continuous
					ventilation provided by two exhaust blowers exhausting to the weather deck. One
					blower provides ventilation for each group, and the two may be cross connected.
					The voids surrounding the tanks together with the gasoline pump room and access trunk
					of each group may be flooded with CO2 gas by pulling fire extinguisher toggles, one
					set of which is at the fourth deck level in trunk A-513-T, and the other just outside
					the access trunk A-516-T door on the second deck. Pulling these toggles also shuts
					down the ventilation blower for the group which is being smothered with C02 gas. To
					further smother a fire, the exhaust and ventilating ducts must be closed. The forward
					and after trunks, pump compartments and tanks compartments are each provided with two
					ventilation control stations; one inside of trunks, the other on third deck at frame
					43 for forward group and at frame 57 for after group. (Wardroom and Warrant Officers'
					Country). These controls shall not be closed while exhaust blowers are in operation.
- As gasoline is withdrawn from any tank, it is replaced with salt water. Tanks are
					operated between the limits of 95% and 5% of their full capacities. The tanks are
					always 100% full of liquid. The salt water is supplied from gravity tanks in the
					gasoline trunks A-513-T and A-516-T and provides sufficient head to insure the suction
					supply to the gasoline pumps. The gasoline pumps supply gasoline to the outlets on
					the flight deck and hangar. Overflow from the salt water gravity tanks discharge
					through the ship's side at frame 41 starboard and frame 59 port at the fourth deck
					level. Salt water gravity tanks are supplied from either the fire main or damage
					control main. The level of the salt water is maintained by a flood valve.
- Gasoline Stowage Spaces
						
							- The forward system of tanks with entrance to its access trunk A-513-T at
							frame 43 amidships on the second deck, is arranged as follows:
							
								| Tank No. | Compartment | Frame | Side | Usable Capacity in Gallons (95%) | 
|---|
 | 50 | A-18-G | 43 | Port | 14,185 |  | 51 | A-18-G | 43 | Stbd. | 14,185 |  | 52 | A-25-G | 43 | Port | 19,686 |  | 53 | A-25-G | 43 | Stbd. | 19,686 |  |  | Total | 67,742 |  
 
- The after group of tanks with entrance to its access trunk A-516-T at frame
							57 amidships on the second deck, is arranged as follows:
							
							| Tank No. | Compartment | Frame | Side | Usable Capacity in Gallons (95%) | 
|---|
 | 54 | A-32-G | 57 | Port | 12,240 |  | 55 | A-32-G | 57 | Stbd. | 24,257 |  | 48 | A-32-G | 57 | Central | 12,240 |  | 56 | A-37-G | 57 | Port | 18,382 |  | 57 | A-37-G | 57 | Stbd. | 21,727 |  | 49 | A-37-G | 57 | Central | 18,382 |  |  | Total | 107,228 |  |  | 95% capacity, both groups | 174,970 |  
 
 
 
- Lubricating Oil System
				
					- Aviation lubricating oil of various grades is carried in six storage tanks in two
					compartments in the hold. The usable capacity of the storage tanks is 17,634 gallons.
					Three storage tanks are located adjacent to the aviation lubricating oil pump room,
					frames 71 to 76, hold; and three are adjacent to the forward diesel generator room,
					frames 76 to 82, hold. Access to these tanks is by trunk A-435-T, third deck; frame
					74.
- There are also five service tanks and three gravity or ready-service tanks. The
					five service tanks are located in the lubricating oil pump room A-709-E. The
					lubricating oil pumps normally take a suction from one of the service tanks and
					discharge to the service loop or to one of the gravity tanks in the island structure
					at the flag bridge level. The service tanks are fitted with steam coils to permit
					heating of the oil as required for cold weather operation. The three gravity tanks
					in the island structure are also fitted with steam coils to provide for heating of
					oil when required.
- There are three oil service stations on the flight deck and four stations on the
					hangar deck. Provision is made for handling three grades of oil. Drain fittings are
					provided to permit draining of good oil back to the service tanks in the event oil from
					planes' tanks is drained at the end of operations in order to fill tanks the following
					day with hot oil. Two dirty oil drain fittings are provided on the flight deck and two
					on the hangar deck. The dirty oil is drained to the ships' fuel oil tanks.
 
 
- Inspection of The Gasoline System
		
			- The entire gasoline system, including all storage tanks, lines, and pump compartments,
			shall be inspected daily by personnel of the gasoline detail. Before entering gasoline
			storage compartments, the precautions outlined in Navy Regulations, 1920, article 1363-7
			(a) and in the Bureau of Construction and Repair Manual shall be carried out.
- The Air Department Integrity Watch shall inspect hourly to determine that intake and
			exhaust openings in the gasoline compartment ventilating system are clear, that the actual
			exhausting of air indicates that the blowers are running and that there is no odor of
			gasoline. The intake and exhaust openings for the forward group are at frame 38 port,
			forecastle level and at frame 38 starboard, forecastle level, respectively; for the after
			group at frame 60, starboard both for the intake and exhaust openings. The blowers are on
			the second deck at frame 43 amidships for the forward group, and at frame 60 amidships for
			the after group.
- Any irregularities noted on these inspections shall be reported immediately to the
			Officer of the Deck and the Air Officer. Gasoline vapor in sufficient concentration for
			the odor to be detected indicates a serious condition, and any person noting the odor
			of gasoline shall report the fact immediately to the Officer of the Deck.
 
- Receiving and Discharging Gasoline
		
			- The Air Officer shall be in charge of the receipt and discharge of gasoline and shall
			see that all necessary stations are manned, and that all necessary safety precautions are
			carried out.
- The First Lieutenant shall be in charge of receiving the lighter or barge alongside,
			and tending it while discharging or loading gasoline.
- The deck divisions shall provide lines and fenders in the parts of the ship where
			necessary.
- The Officer of The Deck Shall
				
					- Clear the side of the ship in the vicinity of the filling connections, located
					at frame 55 starboard and port at the level of the main deck.
- Notify the Executive Officer, Air Officer, and the First Lieutenant when the
					lighter is ready to come alongside.
- Have all ports closed on the side where the gasoline is to be received, and on
					the side or sides from which the salt water is to be discharged overboard.
- Pass the word throughout the ship that the smoking lamp is out.
- See that the incinerator fires are out.
- Notify radio central to secure high frequency transmitter and report when
					secured.
- Station sentries to prevent smoking or other fire hazards. They shall be
					stationed; one on flight deck; one on gallery over lighter; two on the main deck and
					one on the lighter, or barge.
- Hoist the "Baker" flag at the fore truck.
- Allow no power boats, tugs, locomotives, or power driven apparatus to approach
					within 200 feet of the side on which gasoline is being transferred.
- Enter in the log the amount of gasoline received, the time of commencing and
					ending pumping.
- Log the draft of the ship before and after taking gasoline aboard.
 
 
- Fueling Airplanes
		
			- Airplanes shall be fueled in accordance with the instructions of the Air Officer,
			and only by the personnel of the Air Department specifically assigned to the gasoline
			detail.
- Prior to commencing fueling operations, permission shall be obtained from the
			Officer of the Deck, who shall:
				
					- Pass the word throughout the ship that the smoking lamp is out.
- Notify Radio Central to secure the high frequency transmitters and report
					when secured.
- See that the fire fighting apparatus is ready and manned and that there is
					125 lbs. pressure on the fire mains.
 
- There are thirty-two outlets on the flight deck and nine on the main deck. Airplanes
			may be fueled either on the flight deck or in the hangar. Seaplanes may be fueled from
			the two after flight deck outlets at frame 171-172, starboard and port sides, respectively.
			Whenever the gasoline system is secured, all the gasoline in the riser to the above outlets
			shall be drained to the level of the top of the storage tanks, and the completion of this
			operation shall be reported to the Officer of the Deck.
 
- Gasoline Casualties
		
			- In the event of a large gasoline leak, the following action shall be taken by
			responsible officers and men:
				
					- Report the fact immediately to the Officer of the Deck.
- THE OFFICER OF THE DECK SHALL IMMEDIATELY ON NOTIFICATION PASS THE WORD
					"OUT SMOKING LAMP." He shall direct radio central to secure all high
					frequency transmitting.
- Remove personnel from passageways and compartments adjacent to the leak and
					post sentries to prevent traffic in these areas.
- Prevent the throwing of lighted smoking material over the side.
- Stop all machinery in the vicinity of the leak in passageways through which
					vapor laden air currents might pass.
- Close all affected compartments until exhaust ventilation is assured.
- Only gas-tight lights and non-sparking footgear shall be used in the vicinity
					of the leak.
 
- In the event of a rupture in the gasoline line (discharge), such as the main
			discharge line, riser or hose, the following action shall be taken:
				
					- At The Scene of The Rupture
						
							- Take every precaution to prevent the ignition of the spilled gasoline.
- Close the hose valve, riser cutout valve, or main discharge stop valve in
							order to take pressure off the damaged section.
- Notify the gasoline pump room to stop the gasoline pump and drain system.
- Swab up the spilled gasoline and attempt to prevent its spreading.
- Assemble and prepare for immediate use, firefighting apparatus in the vicinity
							of the damage.
- Keep all personnel not engaged in combating the casualty clear of the spilled
							gasoline.
- Stop all electrical machinery in the immediate vicinity.
- Notify the Officer of the Deck and Air Officer.
 
- In The Pump Rooms
						
							- Stop the gasoline pumps.
- Drain the system when so directed by the officer in charge of the gasoline
							system.
 
 
- In the event of a fire on the flight or main deck, while fueling airplanes,
			the following action with reference to the gasoline system shall be taken:
				
					- Fueling crews discontinue fueling and haul gasoline hose clear of the fire area.
- Gasoline detail stop the gasoline pump, secure and drain the system.
- Air Department division officers send men to man gasoline system fire stations.
 
- In the event of a fire in the gasoline tank and pump compartments, the following
			action shall be taken:
				
					- If the compartments are open:
						
							- Remove any personnel in the tank compartments immediately, close the first
							platform manholes, proceed up to the fourth deck, pull the fire extinguisher
              toggles for releasing CO2 into the tank compartments only. Proceed out through
							the second deck access trunk door, close the access trunk door and pull all CO2
							fire extinguisher toggles located outside the trunk on the bulkhead forward of
							the trunk door. Close suction and discharge ventilating valves for the tank
							compartments from the 3rd deck. Notify the Officer of the Deck by nearest
							telephone.
 
- If the compartments are closed
						
							- The presence of fire will be evident only by smoke issuing from the
							ventilating exhaust. The ventilating exhaust for the forward group is located
							at frame 38 starboard under the machine gun platform, and for the after tank
							group at frame 60, starboard, under gallery walkway.
- Do Not open the access trunk door.
- Pull all the CO2 fire extinguisher toggles on the second deck adjacent to but
              outside the access trunk door for the tank group in which there is a fire. This
							action will not only release CO2 into the tank compartment, pump room and trunk
							for the group, but will shut down the ventilating blower for the group as well.
- Close the six ventilating valves for the group affected. The remote control
              handwheels for these valves are located at frame 43 amidships, third deck, in
              compartment A-306-L for the forward group; for the after group they are located
							at frame 57, amidships, third deck, in compartment A-306-LM (Wardroom and Warrant
							Officers' country).
 
 
- In the event that gasoline is inadvertently discharged overboard through the salt
			water gravity tank discharge at frame 41, starboard, and 59 port, the following action
			shall be taken:
				
					- By The Officer of The Deck
						
							- Notify the Executive Officer, the Air Officer, the Officer in charge of
							the gasoline system, and the personnel in the gasoline pump rooms.
- Have all ports closed on the side of the ship affected.
- Order the smoking lamp out. Prevent throwing of lighted smoking material
							over the side.
- Have power boat clear the affected area, but do not allow personnel to start
							their engines.
- Officer of the Deck establish protective boat patrol around affected area.
 
- By the officer in charge of gasoline system:
						
							- The officer in charge of the gasoline system and the gasoline detail shall
							take immediate steps to prevent the discharge of any further gasoline.
 
 
 
- Gasoline Safety Precautions
		
			- All hands shall comply fully with the gasoline safety precautions specified in
			paragraph # 6070.